See Section ALE-24 for Accessories
Littleton, CO USA Phone 303-794-2611 www.norgren.com
B74G
EXCELON design allows in-line or modular
installation
Quick release bayonet bowl
Highly visible, prismatic liquid level indicator lens
Full flow gauge ports
Balanced valve design minimizes effect of variation
in the inlet pressure on the outlet pressure
Modular installations with EXCELON 72, 73, and 74
series can be made to suit particular applications
Excelon
®
74 Series Filter/Regulator
3/8",1/2",3/4" Port Sizes
ALE-12-8
Ordering Information. Models listed include PTF threads, knob adjustment, automatic drain, metal bowl with liquid level indicator, 40 µm element,
relieving diaphragm, 5 to 150 psig (0.3 to 10 bar) outlet pressure adjustment range*, with gauge.
Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.
Main Port Size Model Number Flow
scfm (dm
3
/s) Weight lb (kg)
3/8" B74G-3AK-AD3-RMG 163 (77) 2.62 (1.19)
1/2" B74G-4AK-AD3-RMG 212 (100) 2.59 (1.17)
3/4" B74G-6AK-AD3-RMG 212 (100) 2.55 (1.16)
Alternative Models
B 7 4
-
G
-
Threads Substitute
PTF A
ISO Rc taper B
ISO G parallel G
Adjustment Substitute
Knob K
T-bar T
Diaphragm Substitute
Relieving R
Non relieving N
Gauge Substitute
With G
Without N
Outlet Pressure
Adjustment Range* Substitute
5 to 60 psig (0.3 to 4 bar) F
5 to 150 psig(0.3 to 10 bar ) M
10 to 250 psig (0.7 to 17 bar )** S
Bowl Substitute
Metal with liquid level indicator D
Transparent with guard P
Element Substitute
5 µm 1
25 µm 2
40 µm 3
-
* Outlet pressure can be adjusted to pressures in excess of, and less than, those
specified. Do not use these units to control pressures outside of the specified
ranges.
** Units with 250 psig (17 bar) outlet pressure range are available only with the T-
bar adjustment; therefore substitute T at the 7th digit and S at the 12th position.
Drain Substitute
Automatic A
Manual, 1/4 turn Q
Port Size Substitute
3/8" 3
1/2" 4
3/4" 6